Remote Programming And Monitoring; Environmental Specification - Xantrex XKW 8-350 Operating Manual

Xkw 3000 watt series programmable dc power supply
Table of Contents

Advertisement

Features and Specifications
Specifications
Remote
Programming
and
Monitoring
Remote Start/Stop and Interlock
Remote Analog Programming
Maximum Remote Sense Line Drop
Compensation
Environmental
Specification
Operating Temperature Range
Storage Temperature Range
Humidity Range
Operating Altitude
Storage Altitude
Installation Category
Pollution Degree
24
TTL compatible input. Contact Closure,
12-250 Vac or 12-130 Vdc
Voltage and current programming:
0-5k resistances; 0-5V, 0-10V sources; 0-1mA
sources
OVP programming:
0-5V, 0-10V sources
1 V max.
0-50 °C. From 50-70 °C, derate output 2% per °C
-55 °C to +85 °C
Up to 80% non-condensing
Derate maximum operating temperature by 1°C
per 1,000 feet (30 m) for operation between
5,000 feet and (1,500 m) and 15,000 feet
(4,500 m)
Up to 50,000 feet (15,000 m)
II