Remote Programming And Monitoring - Xantrex XFR 6-200 Operating Manual

Xfr 1200 watt series programmable dc power supply
Hide thumbs Also See for XFR 6-200:
Table of Contents

Advertisement

Remote
Programming
and
Monitoring
Remote Start/Stop and Interlock
Remote Analog Programming (Full
Scale Input)
Remote Monitoring
Remote Programming and
Monitoring Accuracy
Maximum Remote Sense Line Drop
Compensation
Optional Isolated Program and
Readback (V&I)
Optional Digital Control
Release 3.1
Features and Specifications
2.5-15 V signal or TTL-compatible input,
selectable logic. TTL input impedance: 2 k (in
series with one diode drop).
Voltage and current programming inputs
(source must be isolated):
0-5 k, 0-10 k resistances;
0-5 V, 0-10 V (default) voltage sources.
Input impedance (V and I): approximately
100 k.
Output voltage and current: 0-5 V, 0-10 V
(default);
Output impedance (V and I): approximately
221 Ω.
Output short circuit current: approximately
50 mA.
1% zero to full scale output for the default
range.
5 V/line (Line drop is subtracted from total voltage
available at supply output.)
0-5 V (ISOL interface);
input impedance: approx. 200 k;
output impedance: low
RS-232, GPIB interfaces
Specifications
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xfr 1200 watt seriesXfr 7.5-140Xfr 12-100Xfr 20-60Xfr 35-35Xfr 40-30 ... Show all

Table of Contents