6.12 System Shutdown
Routine shutdown may vary depending on your particular requirements. However, it is recommended that
you incorporate the following procedures into your post production shutdown routine.
6.12.1 Post Production Shutdown
To shut down at the end of a production shift:
1. Wait for the dispensing program to complete and verify that all motion has stopped.
2. Unload all workpieces.
3. Move the dispensing head to the front center of the system for easy access.
WARNING!
4. Remove the valve, pump or jet and clean it as instructed in the appropriate valve manual.
5. Clean the dispenser of any spilled fluids.
Cured epoxy is exceptionally difficult to clean!
6. Exit FmXP.
NOTE
7. Exit Windows XP by clicking on the start menu, then shutdown.
8. Make sure Windows XP completely shuts down before turning off the computer.
9. Press the black
WARNING!
6-36
CAUTION!
Follow MSDS recommendations for the proper handling, cleanup, and disposal of
all fluids used with the dispensing
When FmXP closes, the machine will remain powered but the main air
solenoid will close and relieve all air pressure to the system.
button on the S-920 front panel to de-energize the system.
OFF
CAUTION!
Before performing any servicing or parts replacement, the system must be shut
down for service. Failure to do so could cause serious injury to the user and/or
serious damage to the dispensing system. See
system.
2.11 Service Shutdown.