Advertisement

Operating Guide
1000 Series Dispensers
1000XL
1000D
®
In the US: 800-556-3484
In the UK: 0800 585733
In Mexico: 001-800-556-3484
A NORDSON COMPANY

Advertisement

Table of Contents
loading

Summary of Contents for Nordson EFD 1000 Series

  • Page 1 Operating Guide 1000 Series Dispensers 1000XL 1000D • ® In the US: 800-556-3484 In the UK: 0800 585733 In Mexico: 001-800-556-3484 A NORDSON COMPANY...
  • Page 2 Introduction The 1000 Series dispensers provide years of trouble-free, produc- tive service. This Operating Guide will help you maximize the usefulness of your new dispenser. Please spend a few minutes to become familiar with the controls and features of your new dispenser. Follow our recommended testing procedures.
  • Page 3: Table Of Contents

    Contents Getting Started ................4 Specifications First Steps ..................5 Unpacking the Dispenser and Activating your Ten Year No-fault Warranty 1000XL - Hookup ..............6-7 1000XL - Setup for Testing ............8-9 1000D - Hookup ..............10-11 1000D - Setup for Testing ............. 12-13 Testing the 1000 Series Dispensers ........
  • Page 4: Getting Started

    Getting Started We have organized this Guide to provide setup and testing proce- 1000 Series Specifications dures for the 1000XL and 1000D dispensers. Input voltage: Selectable If you have the 1000XL, first review pages 6 - 9 which illustrate how 100/120/220 VAC 50/60 Hz 16/13 VA to hook up the dispenser and what the controls do.
  • Page 5: First Steps

    First Steps First: Unpack and use the checklist enclosed with the Dispenser Kit to identify all items. If there is any discrepancy, please call us immediately. Second: Power and compressed plant air should be available where the dispenser is to be set up. Air pressure should be between 80 and 100 psi (5.5 to 6.9 bar).
  • Page 6 Plant air, 125 psi maximum to regulator. Output from regulator Power should be a minimum of 80 psi, cord maximum of 100 psi. Foot pedal Air input assembly hose Check voltage label on dispenser Adapter assembly 1000XL Blue Male quick-connect, test fluid insert and twist to lock...
  • Page 7: 1000Xl - Hookup

    1000XL -- Hookup Connect the air input hose to a plant air source. Set plant air supply within 80 to 100 psi (5.5 to 6.9 bar). Where required, use an EFD five-micron filter regulator #2000F755 (see Warranty). Attach the air input hose coupling to the dispenser. Pull back metal ring to attach to dispenser.
  • Page 8 CONTROLS and CONNECTIONS Air pressure Time Barrel Air gauge regulator control Vacuum gauge vacuum control Cycle LED Air output Power Timer quick-connect switch bypass Voltage selector and fuse cartridge Cover screw Air input Vacuum transducer Power input air exhaust port receptacle...
  • Page 9: 1000Xl - Setup For Testing

    1000XL -- Setup for Testing Power switch should be off. The amount of material dispensed each cycle depends on the combination of air pressure, time of air pulse, viscosity of material and dispensing tip size. The first step is to remove the tip cap from the pre-filled barrel of blue test material (twist and pull).
  • Page 10 Plant air, 125 psi maximum to regulator. Output from regulator Power should be a minimum of 80 psi, cord maximum of 100 psi. Foot pedal Air input assembly hose Check voltage label on dispenser Adapter assembly 1000D Male quick-connect, Blue insert and twist to lock test fluid...
  • Page 11: 1000D - Hookup

    1000D -- Hookup Connect the air input hose to a plant air source. Set plant air supply within 80 to 100 psi (5.5 to 6.9 bar). Where required, use an EFD five-micron filter regulator #2000F755 (see Warranty). Attach the air input hose coupling to the dispenser. Pull back metal ring to attach to dispenser.
  • Page 12 CONTROLS and CONNECTIONS Air pressure Time Cycle Air gauge regulator control Air output Power Timer bypass quick-connect switch Foot pedal Voltage selector Cover screw receptacle and fuse cartridge Air input Solenoid Power input receptacle...
  • Page 13: 1000D - Setup For Testing

    1000D -- Setup for Testing Power switch should be off. The amount of material dispensed each cycle depends on the combination of air pressure, time of air pulse, viscosity of material and dispensing tip size. The first step is to remove the tip cap from the pre-filled barrel of blue test material (twist and pull).
  • Page 14: Testing The 1000 Series Dispensers

    Testing the 1000 Series Dispensers Making Timed Deposits You are now ready to test the pre-filled, nontoxic, blue test fluid. This material is representative of thick, non-leveling fluids like sealants, pastes or greases. 80° Check your initial settings: Pressure Timer 45°...
  • Page 15 Changing Deposit Size, Drawing Stripes The dot size is determined by the tip diameter, the air pressure output setting and the pulse time. For large dots, use a large tip, higher pressure and more time. Normally, you want to use as short a time pulse as possible.
  • Page 16 Advanced Dispensing System If you dispense thick fluids, several problems may For Thick Fluids occur. First, the repetitive air cycles can bore tunnels through non-leveling fluids, causing spitting and inconsistent deposits. Second, thick Air Pressure Air Pressure fluids contain trapped air that leads to drooling and oozing.
  • Page 17 If you use low to medium viscosity fluids, the white For Thin Fluids ™ SmoothFlow piston has several advantages. First, vacuum adjustment is much less sensitive. Second, the piston prevents fumes from the fluid being exhausted into the work environment. Third, the piston prevents fluid backflow into the dis- penser if the barrel is inadvertently turned upside down.
  • Page 18: How To Use The Vacuum Control

    How to Use the Vacuum Control (1000XL only) The vacuum control allows low viscosity fluids, even water, to be consistently dispensed without dripping between cycles. The vacuum exerts a negative pressure on the fluid in the barrel and prevents dripping. Remove For these tests, you will use the test barrel with the clear fluid.
  • Page 19 If you choose to use the piston, please follow these instruc- Three things to remember tions carefully: If you do not use the piston when dispensing thin fluids: 1. While holding the barrel upright in one hand, twist on an orange tip cap.
  • Page 20: Loading The Barrel Reservoirs

    Loading the Barrel Reservoirs Caution: Do not completely fill barrels. The optimum fill is a maximum 2/3 of the barrel capacity and 1/2 of the barrel capacity when using the LV Barrier ™ If the fluid you are dispensing is pourable, take the barrel, twist on a tip cap and pour your fluid in.
  • Page 21 EFD offers productive alternatives to traditional barrel-loading meth- ods. Here are a few suggestions that can help keep your work area clean, save time and reduce the chance of entrapped air in the fluid. 1. You could use the EFD #920BL barrel loader. Pack the fluid into the 12 ounce cartridge as shown.
  • Page 22: Now, Test Your Fluid

    Now, test your fluid. Barrel Reservoir Selection Remember, each barrel must use the proper size adapter head. Five sizes of barrels and four sizes of adapter heads (30cc and 55cc barrels use the same size adapter head) are provided with this dispenser—3cc, 5cc, 10cc, 30cc and 55cc.
  • Page 23: Troubleshooting

    Troubleshooting 1. Check voltage at wall outlet. NO POWER 2. Check fuse. Replace #7111E. 3. Unplug from wall, remove top cover, visually inspect for any loose or shorted connections. 1. Switch module must be replaced. POWER, BUT NO LIGHT POWER, LIGHT, BUT 1.
  • Page 24 Schematic and Parts 1000D and 1000XL Replacement Parts List 1. 2024-160 1/4" OD x .160" ID tubing 2. 2-2031-1000 Transformer assembly multi input 3. 2-2017A-24XL Foot pedal receptacle 4. 2169 Fitting 1/8 NPT x 1/8 NPT elbow brass 5. 2088 Fitting 1/8 NPT x 1/4 barb brass 6.
  • Page 25 Programmable Timer The heart of each 1000 Series dispenser is the EFD advanced solid- DIP Switch Settings state, digital timer with programmable time ranges and choice of Momentary (press the foot pedal once) or Maintained (hold foot 1 2 3 4 pedal down during time cycle) initiation modes.
  • Page 26: Suggestions & Reminders

    Suggestions & Reminders ™ ™ 1. Always use an EFD SmoothFlow piston or LV Barrier to make barrel loading, dispensing and handling cleaner, safer and more accurate. Caution (1000XL only): If you dispense pourable fluids and choose #2000F755 ™ to use SmoothFlow pistons, do not increase vacuum pressure Five-micron filter regulator...
  • Page 27 ™ ULTRA System Dispensing Components For complete selection and technical details, please refer to EFD Catalog and price list. Barrel adapter assemblies Smooth-flow tapered tips ™ Molded one-piece, yellow, SnapLok adapter Molded polyethylene with UV block. Packaged head with Buna N O-ring, flexible 5/32" OD (50) tips per see-through box with covers for easy hose, male quick-connect and safety clip.
  • Page 28: Ten Year No-Fault Warranty

    EFD makes no warranty whatsoever of merchantability or fitness for a particu- lar purpose. In no event shall EFD be liable for incidental or consequential damages. ® A NORDSON COMPANY Headquarters: 977 Waterman Avenue, East Providence, RI 02914-1378 USA Toll free: 800-556-3484 Mexico: 001-800-556-3484...

This manual is also suitable for:

Efd 1000xlEfd 1000dEfd 1000xle

Table of Contents