Item
1
Target Box
2
Y-axis Controls (forward and back movement)
3
X-axis Controls (side to side movement)
4
Radio Button (Dispenser selected)
5
Z-axis Controls (up and down movement)
NOTE The single arrows
distances and different velocities per mouse click. See Table 6-2.
Table 6-2 Dispensing Head Position Controls: Jog Distance and Velocity
Movement
Axis
X-Y
Z
Notes: (1)
(2) Distance per mouse click on the arrow button.
6-12
1
2
3
4
Figure 6-11 Dispensing Head Position Controls
and double arrows
Distance
(2)
mm (inch)
0.0254 (0.001)
2.54 (0.100)
0.0254 (0.001)
1.27 (0.050)
Default distances and velocities. Refer to the Fluidmove User Guide or Online
Help to modify jog distances and velocities.
Description
move the dispensing head different
mm/sec (in/sec)
2.54 (0.100)
2.54 (0.100)
5
(1)
Velocity
88.9 (3.500)
10.16 (0.400)