Page 1
1 off 20 Mini and micro dispensing solutions for fluids and pastes Installation and Service Manual for ASYMTEK Mixing unit aCCura-Mix-Mini 1 / L with integrated control v.01 Nordson Asymtek...
Page 2
1 INTRODUCTION Dear ladies and gentlemen! First of all, we would like to gratulate you for buying ASYMTEK products, allowing you to work with the latest technology. To be able to avoid malfunctions, some important criteria now follows for commissioning your ASYMTEK product and the servicing afterwards.
Page 3
3. The pump may only be used by healthy people 4. Do only use ASYMTEK spare parts. Damages caused by using other parts are not supported by the ASYMTEK warranty. 5. Should any of this manual not be clear or understandable, please do contact your distributor or write ASYMTEK.com.
Do not let the pump dry run. Make sure that the suction side connection is vacuum proof and that the connection of the pressure side is able to withstand the system pressure. Do not use demineralised water. Nordson Asymtek...
Page 5
5 off 20 Mini and micro dispensing solutions for fluids and pastes 2. Technical description, function and assembly Basically, all ASYMTEK pumps can be used for dosing or transferring (pumping) or emptying applications: Suction Pressure Suction Druckseite* Pressure* Suction...
Page 6
Driving the pump counter clockwise CCW conveys the fluid or paste from the suction side towards the pressure side in picture 1 from left to right. To empty vessels or bottles, in general the flow should go from right to left meaning clockwise CW. ASYMTEK pumps can be used in continuous or indexed applications.
Page 7
The calibration can be performed many times. We suggest to recalibrate every time you change the material or nozzle. Furthermore, recalibration may elongate the use of your ASYMTEK Dosing pump after having used it for a longer period; the process will incorporate possible low wear of the stator.
Page 8
1-2 bar (14.5 - 29 psi), Max. 3 bar (43.5 psi) Pastes till 50.000 mPa.s Max. 50% 3-5 bar (43.5 - 72.5 psi), Max. 6 bar (87 psi) Pastes over 50.000 mPa.s Max. 20% Max. 6 bar (87 psi) Nordson Asymtek...
The suction side pressure and pressure side back pressure together with the dosing velocity are key for the long-life time of your ASYMTEK pump.
Page 10
8 Seal B Use 2 x M3x10 DIN 912 screws to connect the seal housing to the pump housing (9). 7 Seal housing NOTICE: some parts may be made of POM. Do not use high torque! 9 Pump housing Nordson Asymtek...
Page 11
35/36 M5 screw 26 Mixing block 9 Pump housing Use 4 x M3 x 8 (30) screws to connect the mixer support plate (27) with the mixing block (26). Do not use high force! 27 Mixer support plate 30 M3x8 Nordson Asymtek...
Page 12
15 color code ring size. Orange = aCCura 1 Blue = aCCura 2 17 M12 screw nut Green = aCCura 3 White = aCCura 4 Black = aCCura 2 anaerob (full plastic) Nordson Asymtek...
Page 13
The stator (10) must gently slide over the Rotor (3) by means of a turning movement. Do not use high force! Do not just push the rotor into the stator! In case the needed force is too high, you may use vaseline oil or glycol. Nordson Asymtek...
Page 14
If only the stator (10) needs to be exchanged, please refer to point 4.1.1.1 for assembly. Important notice about the seal: Avoid the seals getting damaged by assembly and dismantling. Only use gentle force by hand and no tools to release the seal(s). Nordson Asymtek...
Page 15
The pumps are equipped with a leakage detection in the front of the pump housing (9). Whenever product comes out of the bore, you immediately have to stop the motor and dismantle the unit. See 4.2 picture shows example Nordson Asymtek...
Page 16
4. Worker and service personnel 5. Cleaner and cleaning fluids We suggest using ASYMTEK pumps according the physical and possible properties of the design. Clean always with thoroughness. Furthermore, we suggest to exchange the wearing and tearing parts (see point 7) each 1/2 year. Wet lubricants without particles may need exchange only after 12 months with 8/5 operation mode.
Page 17
17 off 20 Mini and micro dispensing solutions for fluids and pastes 6. Drawings Please ask your dealer or send us an email if you want to receive the PDF or other drawings: This drawing is used as an example. Nordson Asymtek...
Page 19
8. Integration You can use your aCCura for static applications. The body weight and shape have been ergonomically designed for easy use. Furthermore, you can integrate your aCCura-Doser by clamping it onto an XYZ or table top robot. Nordson Asymtek...
Page 20
20 off 20 Mini and micro dispensing solutions for fluids and pastes Nordson Asymtek...