Toshiba TLCS-900/H1 Series Data Book page 422

32bit micro controller
Hide thumbs Also See for TLCS-900/H1 Series:
Table of Contents

Advertisement

Baud Rate (bps)
Modification command
(Note1) When f
(oscillation frequency) is either 16.00,20.00,20.58 or 25MHz, a 115200bps baud-rate is not supported.
OSCH
st
(Notes2) For the 1
-cut sample, the baud-rate can not be changed .
Operation command
C0H
Version Information
FRM1
Table3.21.5(6) Frequency measurement result data
Frequency of oscillator
(MHz)
2000H
(RAM store address)
Description of UART boot-program operation
4)
The boot-program transfers the data sent from PC in extended intel-hex format into the
internal RAM. When the transfer has terminated normally, it calculates the SUM and sends
the result to PC before starting to execute an user-program. The execution start address is
the received first address. This boot-program provides the user's own way to control
on-board programming.
a) Operational procedure
1. Connect the serial cable. Make sure to perform connection before resetting the
TMP92CH21.
2. Set both AM1 and AM0 pins to "1" and reset TMP92CH21.
3.
The received data in the 1st byte means the matching data. When the boot-program
starts in BOOT mode, it goes to a state in which it waits for the matching data to
receive. Upon receiving the matching data, it automatically adjusts the serial channels'
initial baud rate to 9600 bps. The matching data is 5AH.
4.
The 2nd byte is used to echo back 5AH to PC upon completion of the automatic baud
rate setting in the first byte. If the device fails in automatic baud rate setting, it goes to
an idle state.
5.
The 3rd byte to 6th byte are used to send the version management information of the
boot-program in ASCII code. The PC should check that the correct version of the
boot-program is used.
Table3.21.5(3) Baud rate modification command
9600
19200
28H
18H
Table3.21.5(4) Operation command
Operation
Start user-program
Table3.21.5(5) Version management information
ASCII code
46H, 52H, 4DH, 31H
16.000
20.000
22.579
00H
01H
02H
92CH21-418
38400
57600
07H
06H
25.000
32.000
33.868
03H
04H
05H
TMP92CH21
115200
03H
36.000
40.000
06H
07H