Memory Configuration (As From Sw 3) - Siemens SINUMERIK 840C Installation Instructions Manual

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

2 General Reset and Standard Start-Up

2.5 Memory configuration (as from SW 3)

2.5
Standard values
for DRAM
Setting ranges
for DRAM
Part programs
UMS
IKA
FDD/MSD
Block buffer
Measured value
memory
Number of real axes
Data for extended
overstore
Number of measured
value buffers
Note as from SW 4:
1) WS 800 can up to 1024
2-6
More user manuals on
Memory configuration (as from SW 3)
Softw. 3
1 MB Part prog.
512 kB
UMS
256 kB IKA
16 000 points
Note: The ranges cannot be set in software version 3.
SW 4.1 – 4.3
32 kB to
2 760 kB
0
to
1 024 kB
0
to
1 024 kB
0
to
65 535 points
0
or
194/388 kB
0
to
2 760 kB
0
to
approx. 1 800
buffers
0
to
2 760 kB
0
to
700 000
meas. values
Maximum
1 264 kB with 4 MB DRAM
3 264 kB with 8 MB DRAM SW 4.1–4.3
5 160 kB with 8 MB DRAM as from SW 4.4
For UMS at least the memory capacity specified by the WS 800 configuration
station must be entered (not the length of the UMS file transferred).
ManualsBase.com
Softw. 4
4 MB DRAM
704 kB Part prog.
256 kB
UMS
64 kB IKA
4 000 points
240 kB
Block buffer
0 kB
Meas. value mem.
0 kB
FDD/MSD
As from SW 4.4
32 kB to
4 920 kB
0
to
2 760 kB
0
to
1 024 kB
0
to
65 535 points
0
or
194/388 kB
0
to
5 026 kB
0
to
approx. 3 450
buffers
0
to
2 760 kB
0
to
700 000
meas. values
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
04.96
09.95
Softw. 4
8 MB DRAM
704 kB Part prog.
256 kB
UMS
64 kB IKA
4 000 points
240 kB
Block buffer
0 kB
Meas. value mem.
0 kB
FDD/MSD
2 MB free (SW 4.1–4.3)
3.896 MB free (as from
SW 4.4)
or see below (maximum)
As from SW 5.4
1)
Axes 15 to 30
16 kB
each
Axes 1 to 6
49 kB
each
Axes 1 to 30
4 byte
each
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents