Service Parts Disassembly
Registration Sensor
PL3.2.13 (Sensor Photo)
8-80
Caution
The Registration Out Actuator is spring-loaded by a small spring located under
the actuator.
1. Remove the Upper Frame Assembly (SFP page 8-51; MFP page 8-67).
2. Release the hook on the Registration Out Actuator that attaches it to the
Registration Roller Actuator; shift the Registration Roller Actuator to the right.
3. Release the Registration Out Actuator from the hook on the Upper Feeder
Chute, then rotate the Registration Out Actuator up.
Xerox Internal Use Only
http://www.manuals4you.com
Registration Out Spring
Phaser 6500/WorkCentre 6505 Service Manual
s6500-493