Registration Sensor

PL3.2.13
Phaser 6128MFP Service Manual
1. Remove the Upper Frame Assembly (page 8-68).
Caution
The Registration Actuator Out is spring-loaded by a small spring located
under the actuator.
2. Release the hook on the Registration Actuator Out and shift the Registration
Roller Actuator to the right side.
3. Release the Registration Actuator Out from the hook on the Chute Up
(PL3.2.26), then open the Registration Actuator Out.
Service Parts Disassembly
s6128mfp-273
s6128mfp-274
8-29