Error Messages and Codes
IOT Toner (YMCK) CRUM Comm Error
Applicable Error Codes Code
3-154
•
093-925 / 093-950 / 093-951 / 093-952
Troubleshooting Reference Table
Applicable Parts
Toner Cartridge (Y) (PL5.1.24)
■
Toner Cartridge (M) (PL5.1.23)
■
Toner Cartridge (C) (PL5.1.22)
■
Toner Cartridge (K) (PL5.1.21)
■
CRUM Connector (PL5.1.14)
■
MCU Board (SFP PL8.2.13; MFP
■
PL8.3.6)
Toner CRUM Harness Assy
■
(PL5.1.26)
Troubleshooting Procedure
Step Actions and Questions
1
Reseat the Toner Cartridge (Y, M, C or
K).
Does the error still occur when the
power is turned Off and On?
2
Check the connections between the
MCU Board and CRUM Connector (Y,
M, C or K).
Are P/J31 and P/J311(Y) / P/J312 (M) /
P/J313(C) / P/J314 (K) seated
securely?
3
Does the error still occur when the
power is turned Off and On?
4
Check the Toner CRUM Harness Assy
for continuity.
Disconnect P/J11 from the MCU
Board.
Disconnect P/J311(Y) / P/J312 (M) / P/
J313(C) / P/J314 (K) from the CRUM
Connector (YMCK).
Is each cable of P/J31 <=> P/J311(Y) /
P/J312 (M) / P/ J313(C) / P/J314 (K)
continuous?
Xerox Internal Use Only
http://www.manuals4you.com
Wiring and Plug/Jack Map References
"Map 1 - SFP Print Engine" on
■
page 10-6
"Map 4 - SFP MCU Board" on
■
page 10-9
"Map 6 - MFP Print Engine" on
■
page 10-15
"Map 9 - MFP MCU Board and HVPS"
■
on page 10-18
"SFP Xerographics" on page 10-30
■
"SFP Toner Dispenser" on page 10-32
■
"MFP Xerographics" on page 10-43
■
"MFP Toner Dispenser" on page 10-45
■
Yes
Go to step 2.
Go to step 4.
Go to step 4.
Go to step 5.
Phaser 6500/WorkCentre 6505 Service Manual
No
Complete.
Reseat the
connector(s)
securely, then
go to step 3.
Complete.
Replace the
Toner CRUM
Harness Assy.