IOT PHD CRUM ID Error
Phaser 6500/WorkCentre 6505 Service Manual
Applicable Error Code
•
091-916
Troubleshooting Reference Table
Applicable Parts
Imaging Unit (PL4.1.21)
■
MCU Board (SFP PL8.2.13; MFP
■
PL8.3.6)
PHD XPRO Harn Assy (PL9.1.11)
■
Troubleshooting Procedure
Step Actions and Questions
1
Does the error still occur when the
power is turned Off and On?
2
Check the Imaging Unit type.
Is the correct Imaging Unit installed?
3
Does the error still occur when the
power is turned Off and On?
4
Reseat the Imaging Unit.
Does the error still occur when the
power is turned Off and On?
5
Are P/J42 and P/J422 connected
correctly?
6
Does the error still occur when the
power is turned Off and On?
7
Check the PHD XPRO Harness Assy for
continuity.
Disconnect P422 from the Imaging
Unit.
Disconnect J42 from the MCU Board.
Is each cable of P422 <=> J42
continuous?
Xerox Internal Use Only
Error Messages and Codes
Wiring and Plug/Jack Map References
"Map 4 - SFP MCU Board" on
■
page 10-9
"Map 9 - MFP MCU Board and HVPS"
■
on page 10-18
"SFP Xerographics" on page 10-30
■
"MFP Xerographics" on page 10-43
■
Yes
Go to step 2.
Go to step 4.
Go to step 4.
Go to step 5.
Go to step 7.
Go to step 7.
Go to step 8.
No
Complete.
Replace the
Imaging Unit,
then go to step
3.
Complete.
Complete.
Reconnect the
connector(s) P/
J42 and/or P/
J422 securely,
then go to step
6.
Complete.
Replace the
PHD XPRO
Harness Assy.
(SFP,
page 8-128;
MFP,
page 8-148)
3-141