IOT K Mode Solenoid Error 1/2
Applicable Error Codes
3-88
Troubleshooting Procedure (continued)
Step Actions and Questions
6
Check the Sub Motor Harness Assy for
continuity.
Disconnect J22 from the MCU Board.
Disconnect J221 from the Sub Drive
Assembly.
Is each cable of J22 <=> J221
continuous?
7
Reseat the Sub Drive Assembly.
Does the error still occur when the
power is turned Off and On?
8
Check the power to the Sub Drive
Assembly.
Disconnect J22 from the MCU Board.
Are the voltages across J22-2/J22-4
<=> ground on the MCU Board, about
+24 VDC when the interlock switch
(Interlock Harness Assy) is pushed?
•
042-372 / 042-373
Troubleshooting Reference Table
Applicable Parts
Feed Drive Assembly (PL7.1.4)
■
MCU Board (SFP PL8.2.13; MFP
■
PL8.3.6)
Troubleshooting Procedure
Step Actions and Questions
1
Does the error still occur when the power
is turned Off and On?
Xerox Internal Use Only
http://www.manuals4you.com
Yes
Go to step 7.
Go to step 8.
Replace the
Sub Drive
Assembly.
(page 8-113)
Wiring and Plug/Jack Map References
"Map 3 - SFP IP Board, LVPS, and Drive"
■
on page 10-8
"Map 4 - SFP MCU Board" on
■
page 10-9
"SFP Main Drive" on page 10-28
■
"Map 8 - MFP LVPS, IP Board, and
■
Drive" on page 10-17
"Map 9 - MFP MCU Board and HVPS"
■
on page 10-18
"MFP Main Drive" on page 10-41
■
Yes
Go to step 2.
Phaser 6500/WorkCentre 6505 Service Manual
No
Replace the
Sub Motor
Harness Assy.
Complete.
Replace the
MCU Board.
(SFP,
page 8-138;
MFP,
page 8-160)
No
Complete.