15.3

Servo motors

15.3.1

SIMOTICS S-1FL6 feed motors

General technical data
Parameter
Type of motor
Cooling
Operating temperature
Storage temperature
Relative humidity
Installation altitude
Maximum noise level
Thermal class
Vibration resistance
Shock resistance
Rated voltage
Rated current
Holding brake torque
Maximum brake opening time
Holding brake
Maximum brake closing time
Maximum number of emergency
stops
Bearing lifetime
Oil seal lifetime
Encoder lifetime
Paint finish
Degree of protection
Type of construction
Positive rotation
Certification
Restricted emergency stop operation is permissible. Up to 2000 braking operations can be executed with 300% rotor
1)
moment of inertia as external moment of inertia from a speed of 3000 RPM without the brake being subject to an inad-
missible amount of wear.
This lifetime is only for reference. When a motor keeps running at rated speed under rated load, replace its bearing after
2)
20,000 hours to 30,000 hours of service time. Even if the time is not reached, the bearing must be replaced when unu-
sual noise, vibration, or faults are found.
This lifetime is only for reference. When a motor keeps running at 80% rated value and the surrounding air temperature
3)
is 30 °C, the encoder lifetime can be ensured.
378
Description
Permanent-magnet synchronous motor
Self-cooled
0 °C to 40 °C (without power derating)
-20 °C to +65 °C
≤ 90% (non-condensing at 30 °C)
≤ 1000 m (without power derating)
1FL604❑: 65 dB; 1FL606❑: 70 dB; 1FL609❑: 70 dB
B
≤ 49 m/s
2
≤ 25 m/s
(continuous in axial direction); ≤ 50 m/s
2
radial direction); ≤ 250 m/s
24 V ± 10%
1FL604❑: 0.88 A
1FL606❑ : 1.44 A
1FL604❑: 3.5 Nm
1FL606❑ : 12 Nm
1FL604❑: 60 ms
1FL606❑ : 180 ms
1FL604❑: 45 ms
1FL606❑ : 60 ms
2000
1)
> 20000 h
2)
5000 h
> 20000 h
3)
Black
IP65, with shaft oil seal
IM B5, IM V1 and IM V3
Clockwise (default setting in SINAMICS V70 feed drives)
(continuous in
2
(in a short time of 6 ms)
2
1FL609❑: 1.88 A
1FL609❑: 30 Nm
1FL609❑: 220 ms
1FL609❑: 115 ms