NOTICE
Device damage caused by incorrect voltage/insulation tests
Incorrect voltage/insulation tests can damage the device.
Before carrying out a voltage/insulation check of the system/machine, disconnect the devices as all converters and
motors have been subject to a high voltage test by the manufacturer, and therefore it is not necessary to perform an
additional test within the system/machine.
WARNING
Unexpected movement of machines caused by inactive safety functions
Inactive or non-adapted safety functions can trigger unexpected machine movements that may result in serious injury or
death.
Observe the information in the appropriate product documentation before commissioning.
Carry out a safety inspection for functions relevant to safety on the entire system, including all safety-related
components.
Ensure that the safety functions used in your drives and automation tasks are adjusted and activated through
appropriate parameterizing.
Perform a function test.
Only put your plant into live operation once you have guaranteed that the functions relevant to safety are running
correctly.
Note
Important safety notices for Safety Integrated functions
If you want to use Safety Integrated functions, you must observe the safety notices in the Safety Integrated manuals.
WARNING
Malfunctions of the machine as a result of incorrect or changed parameter settings
As a result of incorrect or changed parameterization, machines can malfunction, which in turn can lead to injuries or death.
Protect the parameterization (parameter assignments) against unauthorized access.
Handle possible malfunctions by taking suitable measures, e.g. emergency stop or emergency off.
WARNING
Injury caused by moving or ejected parts
Contact with moving motor parts or drive output elements and the ejection of loose motor parts (e.g. feather keys) out of
the motor enclosure can result in severe injury or death.
Remove any loose parts or secure them so that they cannot be flung out.
Do not touch any moving parts.
Safeguard all moving parts using the appropriate safety guards.
WARNING
Fire due to inadequate cooling
Inadequate cooling can cause the motor to overheat, resulting in death or severe injury as a result of smoke and fire. This
can also result in increased failures and reduced service lives of motors.
Comply with the specified cooling requirements for the motor.
14
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018