16

Parameter list

16.1

Basic machine data

The table below lists the most frequently used machine data only. For more machine data, see SINUMERIK 808D
ADVANCED HMI through the following operations:
+
You can also call the help information for the machine data on the PPU by proceeding through the following steps:
+
Machine data list
No.
Name
11300
JOG_INC_MO
DE_LEVELTRI
GGRD
INC and REF in JOG mode
14510 *
USER_DATA_I
NT[0] ... [31]
User data (INT)
14512 *
USER_DATA_
HEX[0] ... [31]
User data (HEX)
14514 *
USER_DATA_F
LOAT[0] ... [7]
User data (float)
20360
TOOL_PARAM
ETER_DEF_M
ASK
396
1.
Select the system data operating area.
2.
Press this softkey to open the machine data window.
3.
Open the target data list and select the desired data using the cursor keys.
4.
Press this key to call the help information for the selected data.
Note: You can further press this softkey in the current help screen to show a complete list of
all SINUMERIK 808D ADVANCED machine data. In addition, you can also use the following
softkey to search for a specific MD by number in this list:
5.
Pressing this softkey exits the help system.
Default
1
0
0H
0.000000
Turning:
283H
Milling: 0H
Range
Type
-
BOOL
-62,768 to
DWORD
32,767
0 to 0x0FF
BYTE
-3.4e+038 to
DOUBLE
3.4e+038
0 to 0x1FFFFF
DWORD
Unit
Activating
-
PO
-
PO
-
PO
-
PO
-
PO