808D set point cable X51~ ~ ~ ~ X53 connecting with V60 driver instructions
1. 808D PPU interface X51~X53 is defined as axis pulse interface, the standard configuration is
SINAMCIS V60 drive.
2. The detail interface signal for Standard configuration SINAMCIS V60 drive as below:
808D PPU
symbol(colour)
X51~X53 port
1
PULSE+ (green) Positive pulse(NC output signal)
9
PULSE- (yellow)
2
DIR+
10
DIR-
3
ENA+
11
ENA-
65
RST
6
(white/green)
7
M24
ALM1
5
(red/blue)
15
ALM2
8
RDY1 (black)
14
RDY2 (purple)
No.:2012-12-001
( Taking a milling machine for an example)
The description of signal
Negative pulse(NC output signal)
(gray)
DIRECTION +(NC output signal)
(pink)
DIRECTION -(NC output signal)
(brown)
Pulse enable+(NC output signal)
(white)
Pulse enable-(NC output signal)
servo enable(NC output signal)
Alarm Reset(NC output signal)
Servo enable and ALARM RESET
(red)
Ground
Power from the pin 1 of X200,
+24V output
Alarm, from drive side(NC input
(blue)
signal)
Power from the pin 1 of X200,
+24V output
Drive ready signal ( NC input
signal)
I DT SNC M3S
V60 port /pin
Remark
X5 / pin1
5V signal
X5 / pin2
5V signal
X5 / pin3
5V signal
X5 / pin4
5V signal
X5 / pin5
5V signal
X5 / pin6
5V signal
+24V=drive
X6 / pin1
enable
0V=drive disable
X6 / pin2
+ 24V high active
X6 / pin3
X6 / pin4
When alarm is
X6 / pin5
triggered,ALM1,
ALM2 close
X6 / pin6
drive is ready, the
X6 / pin7
line close.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 808D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens 808D

  • Page 1 No.:2012-12-001 808D set point cable X51~ ~ ~ ~ X53 connecting with V60 driver instructions 1. 808D PPU interface X51~X53 is defined as axis pulse interface, the standard configuration is SINAMCIS V60 drive. ( Taking a milling machine for an example) 2.
  • Page 2 : The + 24 V and M signals of X200 must be connected; otherwise, the communication between the PPU and the drives does not function as it should.(reference 808D electrical installation_201205 manual ,the 20 page and the 30 page) If using Siemens standard cable to connect third party drive or using other cable, please be sure good insulation for useless signal cable.