Fault list
Fault
F1000: Internal software
error
Reaction: OFF2
Acknowledgement: POWER
ON
F1001: Floating Point excep-
tion
Reaction: OFF2
Acknowledgement: POWER
ON
F1002: Internal software
error
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F1003: Acknowledgement
delay when accessing the
memory
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F1015: Internal software
error
Reaction: OFF2
Acknowledgement: POWER
ON
F1018: Booting has been
interrupted several times
Reaction: NONE
Acknowledgement: POWER
ON
F1030: Sign-of-life failure for
master control
Reaction: OFF3
Acknowledgement:
IMMEDIATELY
F1611: SI CU: Defect de-
tected
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
464
Cause
An internal software error has occurred.
An exception occurred during an operation
with the Floating Point data type.
An internal software error has occurred.
A memory area was accessed that does
not return a "READY".
An internal software error has occurred.
Module booting was interrupted several
times. As a consequence, the module
boots with the factory setting.
Possible reasons for booting being inter-
rupted:
Power supply interrupted.
CPU crashed.
Parameterization invalid.
After this fault is output, then the module is
booted with the factory settings.
For active PC master control, no sign-of-
life was received within the monitoring
time.
The drive-integrated "Safety Integrated"
(SI) function on the Control Unit (CU) has
detected an error and initiated an STO
Remedy
Evaluate fault buffer.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to later version.
Contact the Hotline.
Replace the Control Unit.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to later version.
Contact the Hotline.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to the latest version.
Contact the Hotline.
Carry out a POWER ON (power off/on) for
all components.
Contact the Hotline.
Carry out a POWER ON (power off/on) for
all components.
Upgrade firmware to the latest version.
Contact the Hotline.
Carry out a POWER ON (power off/on).
After switching on, the module reboots from
the valid parameterization (if available).
Restore the valid parameterization.
Examples:
Carry out a first commissioning, save, carry
out a POWER ON (switch-off/switch-on).
Load another valid parameter backup (e.g.
from the memory card), save, carry out a
POWER ON (switch-off/switch-on).
Note:
If the fault situation is repeated, then this fault
is again output after several interrupted boots.
Contact the Hotline.
Make sure that the high level duration of
the inut pulse is larger than 500 ms.
Carry out a POWER ON (power off/on) for
all components.
Upgrade software.
Replace the Control Unit.
6FC5397-4EP10-0BA8, 07/2018