6.5
PLC machine data
Note
The following tables list the PLC machine data used in the default PLC applications. The machine data not listed below is
reserved for the manufacturer.
USER_DATA_INT
MD14510
PLC interface
address
Machine data -
Integer
14510[12]
DB4500.DBW24 -
14510[13]
DB4500.DBW26 0.1 s
14510[15]
DB4500.DBW30 0.1 s
14510[16]
DB4500.DBW32 0.1 s
14510[17]
DB4500.DBW34 0.1 s
14510[18]
DB4500.DBW36 0.1 s
14510[20]
DB4500.DBW40 -
14510[21]
DB4500.DBW42 0.1 s
14510[22]
DB4500.DBW44 0.1 s
14510[24]
DB4500.DBW48 1 min
14510[25]
DB4500.DBW50 0.01 s
USER_DATA_HEX
MD14512
PLC interface address
Machine data - Hex
14512[16]
Bit 1
DB4500.DBX1016.1
Bit 2
DB4500.DBX1016.2
Bit 3
DB4500.DBX1016.3
Bit 7
DB4500.DBX1016.7
14512[17]
Bit 0
DB4500.DBX1017.0
Bit 1
DB4500.DBX1017.1
Bit 2
DB4500.DBX1017.2
Bit 3
DB4500.DBX1017.3
14512[18]
Bit 2
DB4500.DBX1018.2
Bit 4
DB4500.DBX1018.4
Bit 5
DB4500.DBX1018.5
Bit 6
DB4500.DBX1018.6
Bit 7
DB4500.DBX1018.7
14512[19]
Bit 1
DB4500.DBX1019.1
Bit 2
DB4500.DBX1019.2
Bit 4
DB4500.DBX1019.4
Bit 7
DB4500.DBX1019.7
14512[20]
Bit 0
DB4500.DBX1020.0
138
Unit
Range
0 to 1
5 to 200
5 to 30
1 to 30
5 to 30
1 to 30
2 to 64
5 to 30
30 to 200
5 to 300
100 to 2000
Function
Function of chip conveyor (milling)
Function of safety door (milling)
When the function of safety door is active, it can be triggered by M01/M02
(milling)
Handwheel assignment with the MCP/HMI
Turret (turning); tool magazine (milling)
Clamping function (turning)
Tail stock function (turning)
Selection between handwheel and hand-held unit (0: handwheel; 1: hand-
held unit)
Automatic lubrication at power-on
External signal for spindle stop
Fixed spindle direction
The hardware limit is independent from a PLC program
Each feed axis has a hardware limit switch (activated when Bit 6 = 0)
Function of spindle braking
Password clearing by power-on (0: delete the password; 1: do not delete
the password)
Spindle speed selection in "JOG" mode (0: select the speed set in
MD32020; 1: select the speed set last time)
Manual machine function (this function becomes active if you have in-
stalled licensed turning machine system and called it with a PLC subrou-
tine)
Grey coded switch (0: spindle override controlled by the grey code; 1:
spindle override controlled by triggering user keys)
Function
Layout of the traverse keys
Time for spindle braking
Spindle override 50% key holding on time defined
Spindle override 100% key holding on time defined
Feedrate override 0% key holding on time defined
Feedrate override 100% key holding on time defined
Maximum number of tools
Turret clamping time
Monitoring time when searching for tools
Lubrication interval
Lubrication duration
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018