WARNING
Active implant malfunctions due to electromagnetic fields
Inverters generate electromagnetic fields (EMF) in operation. People with active implants in the immediate vicinity of this
equipment are at particular risk.
As the operator of an EMF-emitting installation, assess the individual risks of persons with active implants. The
following clearances are usually adequate:
No clearance to closed control cabinets and shielded MOTION-CONNECT supply cables
Forearm length (approx. 35 cm clearance) to distributed drive systems and open control cabinets
WARNING
Active implant malfunctions due to permanent-magnet fields
Even when switched off, electric motors with permanent magnets represent a potential risk for persons with heart
pacemakers or implants if they are close to converters/motors.
If you have a heart pacemaker or implant, maintain a minimum distance of 2 m.
When transporting or storing permanent-magnet motors always use the original packing materials with the warning
labels attached.
Clearly mark the storage locations with the appropriate warning labels.
IATA regulations must be observed when transported by air.
WARNING
Unexpected movement of machines caused by radio devices or mobile phones
When radio devices or mobile phones with a transmission power > 1 W are used in the immediate vicinity of components,
they may cause the equipment to malfunction. Malfunctions may impair the functional safety of machines and can therefore
put people in danger or lead to property damage.
If you come closer than around 2 m to such components, switch off any radios or mobile phones.
Use the "SIEMENS Industry Online Support app" only on equipment that has already been switched off.
NOTICE
Damage to motor insulation due to excessive voltages
When operated on systems with grounded line conductor or in the event of a ground fault in the IT system, the motor
insulation can be damaged by the higher voltage to ground. If you use motors that have insulation that is not designed for
operation with grounded line conductors, you must perform the following measures:
IT system: Use a ground fault monitor and eliminate the fault as quickly as possible.
TN or TT systems with grounded line conductor: Use an isolating transformer on the line side.
WARNING
Fire due to inadequate ventilation clearances
Inadequate ventilation clearances can cause overheating of components with subsequent fire and smoke. This can cause
severe injury or even death. This can also result in increased downtime and reduced service lives for devices/systems.
Ensure compliance with the specified minimum clearance as ventilation clearance for the respective component.
WARNING
Unrecognized dangers due to missing or illegible warning labels
Dangers might not be recognized if warning labels are missing or illegible. Unrecognized dangers may cause accidents
resulting in serious injury or death.
Check that the warning labels are complete based on the documentation.
Attach any missing warning labels to the components, where necessary in the national language.
Replace illegible warning labels.