3.3

Mounting the motor

NOTICE
Damage to the motor
If the liquid enters the motor, the motor may be damaged.
During motor installation or operation, make sure that no liquid (water, oil, etc.) can penetrate into the motor. Besides,
when installing the motor horizontally, make sure that the cable outlet faces downward to protect the motor from ingress of
oil or water.
NOTICE
Risk of damage to bearing and bearing grease
Liquid collecting in the flange can have a negative impact on the bearing and bearing grease.
Make sure that the flange is free of liquid, both in the vertical and horizontal mounting positions.
NOTICE
Damage to the encoder
Do not exert any shock at the shaft end; otherwise, the encoder may be damaged.
Note
For detailed information about the motor mounting conditions, see Section "Servo motors (Page 378)".
3.3.1

Mounting the SIMOTICS S-1FL6 motor

3.3.1.1

Mounting orientation and outline dimensions

Mounting orientation
The SIMOTICIS S-1FL6 motor supports flange mounting only and it can be used in the following three types of construction:
Note
When configuring the IM V3 type of construction, pay particular attention to the permissible axial force (weight force of the
drive elements) and the necessary degree of protection.