Subroutine 24 - Aux_3Color_Lamp - Siemens SINUMERIK 808D ADVANCED Series Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED Series:
Table of Contents

Advertisement

Example for calling subroutine 23
6.6.7

Subroutine 24 - AUX_3Color_LAMP

Purpose
Subroutine 24 is used to control the three-color lamp function and can be called in AUX_MCP.
Local variable definition
Inputs
Variable
Type
nodef
BYTE
Outputs
Variable
Type
Red
BOOL
Yellow
BOOL
Green
BOOL
Buzzer
BOOL
Relevant PLC machine data
No.
14512 [21].2
14512 [21].3
Example for calling subroutine 24
146
Description
Reserved
Description
Alarm lamp: red
Alarm lamp: yellow
Alarm lamp: green
Alarm hint: buzzer
Description
Selection of the three-color lamp function (0: deactivate; 1: activate)
Switch of three-color lamp flashing (0: the lamp does not flash; 1: the lamp flashes)
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018