Siemens SINUMERIK 808D ADVANCED Series Commissioning Manual page 374

Hide thumbs Also See for SINUMERIK 808D ADVANCED Series:
Table of Contents

Advertisement

Frame size
Overload capability
Control system
Braking resistor
Protective functions
Cooling method
Environmental
Surround-
conditions
ing air
tempera-
ture
Ambient
humidity
Operating environment
Altitude
Degree of protection
Degree of pollution
Shock
Vibration
374
FSA
300%
Servo control
Built-in
Earthing fault protection, output short-cut protection, overvoltage/undervoltage
protection
Self-cooled
Operation
0 °C to 45 °C: without power derating
45 °C to 55 °C: with power derating
Storage
-40 °C to +70 °C
Operation
< 90% (non-condensing)
Storage
90% (non-condensing)
Indoor (without direct sunlight), free from corrosive gas, combustible gas, oil
gas, or dust
< 1000 m (without derating)
IP20
Class 2
Operation
Operational area II
Peak acceleration: 5 g
Duration of shock: 30 ms
Operation
Operational area II
10 Hz to 58 Hz: 0.075 mm deflection
58 Hz to 200 Hz: 1g vibration
Transport &
5 Hz to 9 Hz: 7.5 mm deflection
storage
9 Hz to 200 Hz: 2 g vibration
Vibration class: 2M3 transportation
FSB
, I
t detection, IGBT overtemperature protection
2)
2
Fan-cooled
FSC
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018