Ambient operating conditions
Temperature
Relative humidity
Atmospheric pressure
Vibration resistance (in operation)
Shock resistance (in operation)
Certification
For the horizontal MCP with override switches;
1)
For the horizontal MCP with a reserved slot for the handwheel;
2)
For the vertical MCP with an override switch for the spindle;
3)
For the vertical MCP with a reserved slot for the handwheel;
4)
15.2

Servo drives

15.2.1

SINAMICS V70 feed drives

Frame size
Article num-
6SL3210-5DE...
ber
Rated output current
Max. output current
Max. supported motor power
Output frequency
Power supply
Voltage/frequency
Permissible supply
configuration
Permissible voltage
fluctuation
Permissible frequency
fluctuation
Rated input current
Power supply capacity
Inrush current
Power loss
Main circuit
1)
Control circuit
Built-in regenerative
resistor
Total
24 VDC power
Voltage
supply
Maximum current
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
Horizontal PPU
Vertical PPU
(161.3/151.3)
(160.3/150.3)
Front: 0 °C to 45 °C
Rear: 0 °C to 50 °C
5% to 90%, without condensation
From 1080 hPa to 795 hPa
10 Hz to 58 Hz: 0.35 mm
58 Hz to 200 Hz: 1g
10 g peak value, 6 ms duration
6 shocks in each of the 3 axes vertical to each other
CE, KC, RCM, and EAC
FSA
12-4UA0
13-5UA0 16-0UA0 17-8UA0 21-0UA0 21-4UA0 21-8UA0
1.2 A
3.0 A
3.6 A
9.0 A
0.4 kW
1.0 kW
0 Hz to 330 Hz
3 phase 380 VAC to 480 VAC, 50/60 Hz
TN, TT, IT
-15% to +10%
-10% to +10%
1.5 A
3.8 A
1.7 kVA
4.3 kVA
8.0 A
8.0 A
31 W
32 W
32 W
32 W
57 W
57 W
120 W
121 W
24 V (-15% to +20%)
Exception: When the SINAMICS V70 works with a motor with brake, the volt-
age tolerance of 24 VDC power supply must be -10% to +10% to meet the
voltage requirement of the brake.
1 A (when using a motor without a brake)
3 A (when using a motor with a brake)
Horizontal MCP
FSB
4.6 A
5.3 A
7.8 A
13.8 A
15.9 A
23.4 A
1.5 kW
1.75 kW
2.5 kW
5.8 A
6.6 A
9.8 A
6.6 kVA
7.6 kVA
11.1 kVA 15.7 kVA 18.9 kVA
4.0 A
4.0 A
4.0 A
76 W
90 W
96 W
35 W
35 W
35 W
131 W
131 W
131 W
242 W
256 W
262 W
Vertical MCP
FSC
11.0 A
13.2 A
33.0 A
39.6 A
3.5 kW
7.0 kW
13.8 A
16.5 A
2.5 A
2.5 A
115 W
138 W
36 W
36 W
339 W
339 W
490 W
513 W
373