Mounting The Simotics M-1Ph1 Main Motor; Mounting Orientation And Outline Dimensions - Siemens SINUMERIK 808D ADVANCED Series Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED Series:
Table of Contents

Advertisement

3.3.2

Mounting the SIMOTICS M-1PH1 main motor

3.3.2.1

Mounting orientation and outline dimensions

Mounting orientation
The SIMOTICS M-1PH1 main motor supports flange mounting and foot mounting as shown below:
Mounting method
Foot mounting
Flange mounting
Minimum clearance between a fan and parts/components mounted by the customer
The minimum clearance between a fan and parts/components mounted by the customer or the air discharge opening, and
the minimum clearance S between the air intake/air discharge opening and adjacent components must be maintained.
Shaft height (mm)
Fan mounting
100
Non-drive end axial, can be rotated through 180° 30
132
Non-drive end radial, can be ordered differently
from the mounting type
Motor dimensions
Shaft height 100 mm: flange mounting (unit: mm)
Motor
1PH1101-1❑F12-❑GA0
1PH1103-1❑F12-❑GA0
1PH1103-1❑D12-❑GA0
1PH1105-1❑F12-❑GA0
1PH1105-1❑D12-❑GA0
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
Standard type of construction
IM B3
IM B5
L
419
449
449
499
499
Rotated type of construction
IM V5
IM V1
Minimum clearance S (mm)
60
67