10.3 Commissioning measuring cycles for HMI-Advanced PCU50 powerline up to SW 06.03.18
and/or SW 06.04.08
10.3
Commissioning measuring cycles for HMI-Advanced PCU50 powerline
10.3
up to SW 06.03.18
and/or SW 06.04.08
10.3.1
Requirements
Successful execution of steps 0.1, 0.2 and as an option step 0.3 from chapters 10.2.2, 10.2.3
and 10.2.4.
10.3.2
Step 1 – load definition files
10.3.2.1
General
Variant 1
Modules GUD5.DEF and GUD6.DEF are not active in the NCU (HMI/Services/Manage
data).
• Transfer GUD5.DEF and GUD6.DEF from the subdirectory "define" (supplied on floppy
• Select the DEF modules singly (HMI/Services/Manage data) and press softkey "Activate".
Variant 2
Modules GUD5.DEF and GUD6.DEF are active in the NCU (HMI/Services/Manage data).
• Save data to the archive or floppy disk using "Services", "Data out", folder "NC-active
• Select definition files GUD5.DEF and GUD6.DEF individually in the menu "Services",
• Transfer GUD5.DEF and GUD6.DEF from the subdirectory "define" (supplied on floppy
• Select the DEF modules singly (HMI/Services/Manage data) and press softkey "Activate".
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
disk) to the HMI using "Services", "Data in" from the floppy disk or using RS-232-C.
data", "User data".
directory "Definitions" and unload by pressing the softkey "Unload".
disk) to the HMI using "Services", "Data in" from the floppy disk or using V.24.
Note
Without measuring in JOG
Without this function, commissioning continues from step 2 in chapter 10.3.3.
Start-up (hardware)
10-5