4.2.7
Rejection, repetition, end of measurement
4.2.7.1
Rejection and repetition of measurements
The last measurement (Px) can be declared invalid any number of times by pressing the
assigned softkey "Px stored"
. The softkey is then deactivated (grayed out).
Pressing "NC start" again repeats this measurement and the "Px stored" softkey is then
reactivated (black text).
Example
Vertical softkeys P1 to P4 - inactive:
4.2.7.2
Terminating the measurement
If all "Px saved" softkeys are active, then a vertical "calculate" softkey is displayed.
When this softkey is pressed, the measuring points are finally confirmed/acknowledged and
the translatory and rotary offset values are calculated. The result is immediately entered into
the pre-selected "zero offset". If this is identical with "ZO when measuring", the offset values
become immediately effective. This means that the measurements have been completed.
For offsets/corrections, that required e.g. a new alignment/orientation of the measuring probe
or the rotary table, the user is provided with a support function to activate the determined ZO
offset in the JOG mode. Once the "Calculate" softkey has been pressed, this is shown and is
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring in JOG
4.2 Workpiece measurement
4-35