Parameter
Parameter
_MVAR
_SETVAL
_ID
_MA
_TNUM
_TNAME
_KNUM
_CPA
_CPO
_STA1
_SZA
_PRNUM
7.2.4.11
Measure rectangle - CYCLE_977_979C
With CYCLE_977_979C
Softkeys
measuring variants xxx5 and xxx6 of measuring cycle CYCLE977 can be parameterized.
Parameter
Parameter
_MVAR
_SETV[0]
_SETV[1]
_ID
_SZA
_SZO
_TNUM
_TNAME
_KNUM
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
7.2 Measuring cycle support in the program editor (up to measuring cycles SW 5.4)
Type
Value
INTEGER
INTEGER
>0
REAL
REAL
INTEGER
>0
INTEGER
≥0
STRING
INTEGER
≥0
REAL
REAL
REAL
REAL
INTEGER
>0
→
Type
Value
INTEGER
>0
REAL
REAL
REAL
REAL
REAL
INTEGER
≥0
STRING
INTEGER
≥0
Meaning
Selection: Angular position
977...paraxial measurement / 979...measurement at an angle
Measuring variant
Setpoint
Infeed path
Number of measuring axis 1, 2
Tool number for automatic offset
Tool name with active tool management
Offset number
D number for measurement/ZO number for calculating zero
offset
Center groove, web 1st axis
Center groove, web 2nd axis
Start angle
Safe area (for paraxial measurement only)
Probe number
→
→
Meaning
Measuring variant
Setpoint length
Setpoint width
Infeed path
Protection zone length
Protection zone width
Tool number for automatic offset
Tool name with active tool management
Offset number
D number for measurement/ZO number for calculating zero
offset
Miscellaneous functions
7-19