6.5.3.3

Operational sequence

Position before measuring cycle call
The probe must be positioned opposite the surface to be measured.
Position after end of measuring cycle
On completion of measurement, the probe is positioned facing the measuring surface at
distance _FA.
Notice
Precise measurement is only possible with a probe calibrated under the measurement
conditions, i.e. working plane and measuring velocity are the same for both measurement
and calibration. If the probe is used in the spindle for a powered tool, the spindle orientation
must also be considered. Deviations can cause additional measuring errors.
6.5.4

1-point measurement with reversal and tool offset

6.5.4.1

General information

Function
With this measuring cycle and the _MVAR=1000 measuring variant, the workpiece actual
value is ascertained with reference to the workpiece zero in the measuring axis by acquiring
two opposite points on the diameter.
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring Cycles for Turning Machines
6.5 CYCLE974 workpiece: 1-point measurement
6-75