Miscellaneous functions
7.4 Measuring result screens
Recompiling
Recompilation of programs allows you to change existing programs using the cycle support.
When recompiling measuring cycle calls, please note that a field of defaults for programming
is active (_MZ_MASK) in addition to the screen forms. If there has been a change in this
settings between program creation and recompilation, the changes will also be included in
the program.
Programs with measuring cycle calls cannot be recompiled after a change in the type of tool
programming, i.e. change in the machine data setting
• MD 18102: MM_TYPE_OF_CUTTING_EDGE
• MD 18080: MM_TOOL_MANAGEMENT_MASK
.
7.4
Measuring result screens
7.4
Function
Measurement result displays will be shown automatically during measuring cycle runtime if
_CHBIT[10]=1. If _CHBIT[10]=0 (default setting), the measurement result displays are now
shown.
Depending on the setting in _CHBIT[11] and _CHBIT[18]
• the measurement result displays are automatically deselected at the end of measuring
• the measurement result displays must be acknowledged with the NC start key
• The measurement result displays are retained until the next measuring cycle call
The measuring cycles can display different measuring result screens depending on the
measuring variant:
• Calibrating tool probes
• Measuring the tool
• Calibrating workpiece probes
• Workpiece measurement
7-34
cycle (_CHBIT[11]=0, _CHBIT[18]=0)
or
(_CHBIT[11]=1, _CHBIT[18]=0). In this case, the measuring cycle outputs the message:
"Please acknowledge measurement result screen with NC start"
or
(_CHBIT[11]=0, _CHBIT[18]=1).
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring cycles