Calibrating Probe Radius - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Result
Calibration is performed automatically as soon as you press "NC Start". Trigger value and
length offset L1 are stored.
4.2.2.3

Calibrating probe radius

General information
With the "radius" selection, the probe can be calibrated in the axes of the working plane in a
suitable hole (geometrical accuracy, low surface roughness) and precisely known diameter
or in calibration ring.
Approaching the calibration ring
Position the probe roughly in the hole center and at calibration depth.
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring in JOG
4.2 Workpiece measurement
4-11