Step 6 - Activate Measuring Cycle Support, Configure; Step 7 - Load And Activate Measuring In Jog - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

10.3 Commissioning measuring cycles for HMI-Advanced PCU50 powerline up to SW 06.03.18
and/or SW 06.04.08
10.3.7
Step 6 – activate measuring cycle support, configure
The entry softkeys "Measure turning" and "Measure milling" for measuring cycle support are
activated in the file AEDITOR.COM ("Services" are in the directory "Standard cycles") by
deleting the semicolons in front of the following lines:
;HS14=($83530,,se1)
;PRESS(HS14)
;LS("D_mess","MZ_SKL.COM",1)
;END_PRESS
;HS15=($83531,,se1)
;PRESS(HS15)
;LS("F_mess","MZ_SKL.COM",1)
;END_PRESS
The entry softkey "Measuring cycles" in the "Commissioning" area is activated in the file
STARTUP.COM ("Services" are in the directory "Standard cycles") by deleting the
semicolons in front of the following lines:
;HS15=($83070,,se1)
;PRESS(HS15)
;LS("Meas. c")
;END_PRESS
Press the etc. key ">" in the "Commissioning" area, then press the softkeys "Measuring
cycles", "Automatic measuring". A start-up screen in which the settings for the measuring
cycle screens can be undertaken is then displayed . The settings for the start-up screen are
saved in an integer type GUD field "_MZ_MASK". This is located in the GUD6 under NCK
global data.
10.3.8

Step 7 - load and activate measuring in JOG

• Load the files for measurement in JOG (see Subsection 9.3.4 "Loading files for
• Activate softkeys for measurement in JOG in file "MA_JOG.COM" by deleting semicolons.
;HS4=($83358,ac7,se1)
;PRESS(HS4)
;LM("Messen1","jog_meas.com")
;END_PRESS
;HS5=($83359,ac7,se1)
;PRESS(HS5)
;LM("Messen2","jog_meas.com")
;END_PRESS
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
measurement in JOG").
The semicolons before the following lines must be deleted:
Start-up (hardware)
10-9

Advertisement