Siemens SINUMERIK 840D sl Programming Manual page 511

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

CYCLE997
_RF
REAL
_SETV[8]
REAL
_STA1
REAL
_TNVL
REAL
_TSA
REAL
_VMS
REAL
>=0
CYCLE998
Parameter
Type
GUD5
_CALNUM
INT
_CORA
REAL
0...359.5
_CPA
REAL
_CPO
REAL
_EVNUM
INT
_FA
REAL
>0
_ID
REAL
_INCA
REAL
_K
INT
_KNUM
INT
_MA
INT
>0
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Workpiece measurements
Velocity for intermediate paths on circular path (G2 or G3)
(or _MVAR=xx1109 only, measuring at an angle)
Starting angle (for _MVAR=xx1109 only, measuring at an angle)
----
(for _VMS=0: 150 mm/min (if _FA=1); 300 mm/min (if _FA>1))
Workpiece measurements
Abscissa (_MA=1) / ordinate (_MA=2) / applicate (_MA=3)
1 angle
Distance between measuring points P1 and
P2 in offset axis
----
1...99
automatic offset in ZO
G54...G57
G505...G599
1000
automatic offset in basic frame G500
1011...1026
automatic ZO correction in 1st to 16th basic frame
2000
automatic ZO in system frame
9999
automatic ZO correction in active frame G54...G57, G505...G599 or with active
G500 in the last active channel-specific basic frame
Offset axis/measuring axis
102: Offset axis
A.1 Overview of measuring cycle parameters
Setpoints, center point of the spheres (balls)
Safe area
Variable measuring velocity
Possible measuring axes
for G17: X=1 / Y=2 / Z=3
for G18: Z=1 / X=2 / Y=3
for G19: Y=1 / Z=2 / X=3
Measuring with automatic ZO correction
----
Offset angular position
(only active if mono probe)
----
----
----
Measurement path in mm
Distance between measuring points P1 and P2 in
----
without/with automatic offset of the ZO memory
0 without offset
Limit for triangle distortion
(for _MVAR=x1x109 only, measure 3 spheres
and ZO correction)
1 angle
abscissa
Setpoint or angle in ordinate
----
Appendix
A-21

Advertisement

Table of Contents
loading

Table of Contents