Upgrading Measuring Cycles; General Information; Upgrading Measuring Cycles For Hmi-Advanced Pcu50 Powerline Up To Sw 06.03.18 And/Or Sw 06.04.08 - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

10.7

Upgrading measuring cycles

10.7
10.7.1

General information

Upgrading measuring cycles is basically performed in the same order as initial installation.
Special notes:
• Only use files with the same measuring cycle software version. Do not mix files with
• Always heed the up-to-date information in SIEMENSD.TXT / SIEMENSE.TXT.
• Whether you need to increase the memory configuring machine data depends on the
• When performing a software upgrade, make sure the variable values in the existing DEF
• The measuring cycle data usually only has to be adjusted when upgrading an initial
The next steps of upgrading depend on the HMI hardware and software used.
HMI version (HMI\Diagnosis\Service displays\Version\HMI)
1.
2.
3.
10.7.2
Upgrading measuring cycles for HMI-Advanced PCU50 powerline up to SW
06.03.18 and/or SW 06.04.08
Note
Refer to Chapter 10.3.
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
different versions!
state of the machine and the previous measuring cycle version.
files are preserved. These should first be saved if necessary.
release of 5.x (or 4.x). When upgrading within measuring cycles SW 6, only the values
set by previously archiving the NC-active data need be reconstructed (unless other
settings are specified specifically in the SIEMENSD.TXT / SIEMENSE.TXT).
HMI-Advanced PCU50 powerline
up to SW 06.03.18 or up to SW 06.04.08
as of SW 06.03.19 or as of SW 06.04.10
HMI-Advanced PCU50 solution line
HMI-Embedded PCU20 powerline
Start-up (hardware)
10.7 Upgrading measuring cycles
→ continue with section 10.7.2
→ continue with section 10.7.3
→ continue with section 10.7.3
→ continue with section 10.7.4
10-21