Data description
9.2 Cycle data
• Length of workpiece probe relative to end of probe ball.
• Static measurement result display.
• No repeat of an unsuccessful attempted measurement.
• Retraction of the probe from the measuring point at 80% of rapid traverse velocity.
Example:
%_N_MZ_VALUE ASSIGNMENT_MPF
;$PATH=/_N_MPF_DIR
;(date) pre-assignment of meas. cycle data to machine_1
N10 _TP[0,6]=20 _TP[1,6]=20 _TP[0,8]=101
_TP[1,8]=101
N20 _CBIT[0]=1
N30 _CBIT[14]=1
N40 _CHBIT[10]=1 _CHBIT[11]=0 _CHBIT[18]=1
N50 _CHBIT[15]=1
N60 _CHBIT[16]=1
N65 _SPEED[0]=80
N99 M2
9-14
;Specification of disk diameter and
type
;of tool probe
;Preset measurement repeat bit
;Length of workpiece probe relative to
;end of probe ball
;Bits for static
;display of meas. result.
;Measurement abort after unsuccessful
;attempt
;Retraction from measuring point at
;% ;rapid traverse velocity defined in
;_SPEED[0]
;Reduction of rapid traverse to 80 %
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0