Workpiece probe 1, used as tool T9, D1, is
to be used.
The probe is already calibrated. Arrays for
workpiece probe 1: _WP[0, ...]
The following is entered under T9, D1 in
the tool offset memory:
Tool type (DP1):
Length 1 - geometry (DP3):
Radius - geometry (DP6):
Length 1 (L1) must refer to the center of
the probe ball (_CBIT[14]=0), as for
calibration.
Careful when positioning! Radius R in
length (L1) is ignored.
%_N_INCLINEDMEAS_MPF
N10 G54 G17 G90 T9 D1
N20 M6
N30 X70 Y-10
N40 Z40
N60 _MVAR=106 _SETV[0]=30 _ID=40
_KNUM=0 _RA=0 _STA1=8 _INCA=12 _TSA=5
_PRNUM=1 _VMS=0 _NMSP=1 _FA=5 _EVNUM=0
N520 CYCLE998
N530 G0 Z160
N540 M30
Explanation of example
Both measured angles are entered in result field _OVR[ ]. A ZO correction is not applied
(_KNUM=0).
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring Cycles for Milling and Machining Centers
5.7 CYCLE998 workpiece: Angle measurement and ZO determination
710
L1 = 50.000
R = 3.000
;Select T No. probe
;Activate offsets
;Position probe in X/Y plane above
;measuring point
;Position Z axis at measuring point level
;and select tool offset
;Set parameters for measuring cycle call
;Measuring cycle for measuring the oblique
;plane
;Traverse up Z axis
;End of program