Modifying The Gud7 Data Block - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

24006
CHSFRAME_RESET_MASK
MD number
Reset behavior of the channel-specific system frame, actual value setting and scratching (basis
reference)
Note: MD only relevant if frames are configured (MD 28082 SYSTEM_FRAME_MASK)
Default setting: 0
1)
Default setting: 0
2)
For measuring in JOG: at least 1
(Bit 0 = 1)
Changes effective after RESET
Data type DWORD
Significance:
Bit 0: 1 system frame for PRESET and scratching (basis reference) is active after RESET.
1) up to NCK software version 59.xx.yy
2) as of NCK software version 63.xx.yy
24007
CHSFRAME_RESET_CLEAR_MASK
MD number
Clear system frames on RESET
Note: MD only relevant if frames are configured (MD 28082 SYSTEM_FRAME_MASK)
Default setting: 0
1)
Default setting: 0
2)
For measuring in JOG: Bit 0 = 0
Changes effective after RESET
Data type DWORD
Significance:
Bit 0: 0 system frame for PRESET and scratching (basis reference) is not deleted at RESET.
1) up to NCK software version 59.xx.yy
2) as of NCK software version 63.xx.yy
9.3.2

Modifying the GUD7 data block

General information
Measurement in JOG requires data definitions in data block GUD7.DEF.
Different procedures are followed depending on the configuration of the overall system.
1. If the "ShopMill" programming interface is installed on the control, then all of the required
2. From SW 6.02.17 of the measuring cycle package, the definition files GUD7.DEF and
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Min. input limit: 0
Min. input limit: 0
GUD data are already active. No reloading or additional modification of definition blocks
is required.
SMAC.DEF – are split-up. Now a differentiation is made between basis definition files and
application-specific definition files. All applications, measuring cycles, technology cycles,
ShopMill etc. only incorporate their own application-specific definitions. For this purpose,
new cycle files GUD7_xxx.DEF and SMAC_xxx.DEF have been introduced, and are
located in the HMI data management, in the definition directory DEF.DIR. This means,
when measuring in JOG, from measuring cycles SW 6.02.17, the data block
GUD7_MC.DEF supplied must be used. A secondary condition/limitation is that file
GUD7.DEF must be used – also for measuring cycles from SW 6.02.17
Protection level: 2/7
Protection level: 2/7
Data description
9.3 Data for measuring in JOG
Max. input limit: 07FFFH
Units: HEX
Applies as of SW SW 2
Max. input limit: 07FFFH
Units: HEX
Applies as of SW SW 2
9-41