Measuring in JOG
4.2 Workpiece measurement
Enter details in input form
Enter the known dimension of the calibration ring diameter.
Note the settings in data block GUD6:
• Active zero offset during measurement:
• Active working plane during measurement:
Result
Calibration is performed automatically as soon as you press "NC Start".
The precise position of the hole center is determined first. After that, in both axes of the
plane and in each of the two directions, the 4 switching points within the hole are determined
and stored as trigger values in the probe's array.
4.2.3
Measure edge
4.2.3.1
General information
Prerequisite
The workpiece probe is the active tool with activated tool offsets in the spindle and is already
calibrated (refer to "Calibrating workpiece probe" chapter).
Selection display
After selecting "edge", a selection display is shown containing the following options:
• "Setting the edge"
• "Orienting the edge"
• "Distance 2 edges"
4-12
Variable _JM_I_[4].
Variable _JM_I_[3].
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring cycles