Programming Example - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Measuring Cycles for Milling and Machining Centers
5.3 CYCLE976 calibrate workpiece probe
Parameter
Parameter
_MVAR
_SETVAL
_MA
_MD
_PRNUM
_STA1
The following additional parameters are also valid:
_VMS, _CORA, _TZL, _TSA, _FA and _NMSP.
_CORA only relevant for monodirectional probe.
See also
Variable measuring velocity: _VMS (Page 2-14)
Offset angle position: _CORA (Page 2-14)
Tolerance parameters: _TZL, _TMV, _TUL, _TLL, _TDIF and _TSA (Page 2-15)
Measurement path: _FA (Page 2-16)
Multiple measurement at the same location: _NMSP (Page 2-19)
5.3.2.2

Programming example

Calibrating a workpiece probe in the X-Y plane, known hole center point
Workpiece probe 3, used as tool T9, D1, is to be recalibrated in a known hole with
MPx=100,000, MPy=80,000, D=110,246 mm
in axes X and Y in both axis directions with G17 and paraxially (to redetermine trigger values
_WP[i,1] to _WP[i,4].
The positional deviation (skew _WP[i,7], _WP[i,8]) and precise ball diameter _WP[i,0] of the
probe is also to be ascertained.
5-34
Data type
xxxx01
REAL, >0
1, 2
0 positive axis direction
1 negative axis direction
>0
REAL
Meaning
Calibration variant
Calibration setpoint = diameter of hole
Meas. axis, only for _MVAR= xx1xx01, = xx2xx01
(only 1 axis or only 1 axis direction)
Meas. axis, only for _MVAR= xx1x01
(calibrate one axis direction only)
Probe number
Starting angle, only for _MVAR= 1xxx01
(calibration performed at this angle)
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring cycles

Advertisement

Table of Contents
loading

Table of Contents