2.2.4.3 Switch (Normal/Open) Failure FIP

Procedure
Enter DC330[XXX-XXX]. Turn the switch ON. Is [LOW] displayed?
Y
N
Is +5VDC measured between the switch pin-2 (+) and the GND (-) ?
Y
N
Check the connection between the switch pin-2 and the PWB pin-3 for an open cir-
cuit and poor contact.
If no problem is found, replace the PWB.
Is +5VDC measured between the switch pin-1 (+) and the GND (-) ?
Y
N
Replace the switch.
Check the connection between the switch pin-1 and the PWB pin-4 for an open circuit
and poor contact.
If no problem is found, replace the PWB.
Turn the switch OFF. Is [HIGH] displayed?
Y
N
Disconnect the switch connector. Is [HIGH] displayed?
Y
N
Check the connection between the switch pin-2 and the PWB pin-3 for a short circuit.
If no problem is found, replace the PWB.
Replace the switch.
Check the installation of the switch.
If no problems are found, replace the switch.
Status Indicator RAPs
2.2.4.3, 2.2.4.4
Figure 1 2003
2.2.4.4 Solenoid/Clutch Not Energized Failure FIP
Procedure
NOTE: Before performing this FIP, ensure that there is no (mechanical) operation failure with
the solenoid and the clutch.
Enter DC330[XXX-XXX] and turn it ON. Is +24VDC measured between the PWB pin-3 (+)
and the GND (-)?
Y
N
Is +24VDC measured between the solenoid/clutch pin-2 (+) and the GND (-) ?
Y
N
Is +24VDC measured between the solenoid/clutch pin-1 (+) and the GND (-) ?
Y
N
Check the connection between the PWB pin-4 and the solenoid/clutch pin-1 for
an open circuit and poor contact.
If no problem is found, replace the PWB.
Replace the solenoid/clutch.
Check the connection between the PWB pin-3 and the solenoid/clutch pin-2 for an open
circuit and poor contact.
Replace the PWB.
08/2012
2-60
Figure 1 2004
WorkCentre 5021/5019
Initial Issue