3.3.1 IOT Image Defect Sample

This section describes some Defect Samples and the actions to be taken in case of the follow-
ing IOT problems:
IDS1
Auger Mark
IDS2
Strobing (27mm or 13.5mm Pitch Density)
IDS3
White Streaks (Process Direction)
IDS4
Black Bands
IDS5
Toner Contamination
IDS6
Toner Splattering
IDS7
White Spots (Irregular)
IDS8
Regular Blank Areas in Process Direction (Spots, Streaks, Bands etc.)
IDS9
Regular Toner Contamination in Process Direction (Spots, Streaks, Bands etc.)
IDS10
Regular Toner Contamination in Process Direction (Side 2)
Initial Issue
WorkCentre 5021/5019

3.3.2 IIT Image Defect Sample

This section describes some Defect Samples and the actions to be taken in case of the follow-
ing IIT problems:
IDS11
Moire Due to Interference With Copy Documents
IDS12
Light Background Due to Background Suppression in Copies of Documents With
Frames
IDS13
Background Smear When Using Platen Copy With Non-Standard Documents
IDS14
Fluctuation In Background Suppression Values for Copies of Documents With
Medium Density
IDS15
Defects Related To Scan Print
08/2012
3-15