Xerox WorkCentre 5021 Service Documentation page 368

Hide thumbs Also See for WorkCentre 5021:
Table of Contents

Advertisement

6.4.2.9 HFSI Read/Clear
Purpose
Reads the HFSI Counter that is used as the guideline for replacement of consumables and
clear it if neccessary.
NOTE: For more details on the HFSI Counter Code, refer to 6.3.4 in Chapter 6.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. and press the [Start] button.
3.
The read value of the HFSI Counter for the monitored component is displayed on the UI.
4.
Pressing [Clear] and then [Start] clears the read value of the HFSI Counter to '0'.
5.
Pressing the [Clear All] button returns you to the [Chain-Link Number Entry] screen.
Initial Issue
WorkCentre 5021/5019
6.4.2.10 Jam Counter Reset
Purpose
To clear all the Jam Counters at one go.
Check the completed [Jam Counter Reset] at the [Paper Jam History] of [ERROR History
Report].
Procedure
1.
Enter the CE Diag Mode and input 998-981 in the Chain-Link.
2.
Pressing the [Start] button transitions to the [Check Initialization] screen. At this time, the
[CLR] and the [Start] button will be flashing.
3.
Pressing the [Start] button starts the clearing of all [Jam Counter].
An animation will be displayed to indicate that it is in progress.
08/2012
6-99
Figure 1 j0lj64003
General Procedures
6.4.2.9, 6.4.2.10