Xerox WorkCentre 5021 Service Documentation page 42

Hide thumbs Also See for WorkCentre 5021:
Table of Contents

Advertisement

061-321 ROS Motor Fail
BSD-ON:CH6.4
The number of rotation of the ROS Motor did not come within the standard range within the
specified time (5 s) after the ROS Motor On.
Cause/Action
1.
Turn the power OFF and ON.
2.
Check whether the Drum Cartridge is installed.
3.
Check the ROS Motor (Output Check [061-001]) for operation failure.
4.
Check the LD +5VDC power supply of the LD PWB
5.
If no problem is found, replace the following parts in sequence:
ROS Assembly
(PL
2.1)
ESS/MCU PWB
(PL
18.1)
Initial Issue
WorkCentre 5021/5019
J140
pin-8.
08/2012
2-31
061-325 No SOS Fail
BSD-ON:CH6.4
After the detection of ROS Motor Ready (steady rotation), the SOS interval was detected to be
longer than the reference value 5 times in a row.
Cause/Action
1.
Turn the power OFF and ON.
2.
Check whether the Drum Cartridge is installed.
3.
Turn OFF the power and check the connections between the ESS/MCU PWB J410,
J411
and the LD PWB J140,
J160
4.
If no problem is found, replace the following parts in sequence:
ROS Assembly
(PL
2.1)
ESS/MCU PWB
(PL
18.1)
for open circuits, short circuits, and poor contacts.
Status Indicator RAPs
061-321, 061-325

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5019

Table of Contents