REP 1.5.1 LED Lamp PWB

Parts List on
PL 1.5
Removal
When turning OFF the power switch, check that the 'Data' lamp is OFF and that there is
no Job in progress.
Turn OFF the power switch and make sure that the screen display turns OFF.
Check that the power switch is OFF and unplug the power plug.
1.
Remove the Platen Cover or the DADF.
2.
Remove the IIT Top Cover.
(REP
1.2.1)
3.
Move the IIT Carriage to the opening of the Frame. (Figure 1)
(1) Rotate the gear in the direction of the arrow.
(2) Move the IIT Carriage to the opening (Arrow A) of the Frame.
Figure 1 j0lj40107
4.
Disconnect the connector of the LED Housing. (Figure 2)
(1) Lower the block of the Connector Housing in the direction of the arrow.
(2) Pull out and remove the LED Cable in the direction of the arrow.
Repairs and Adjustments
REP 1.5.1
WARNING
(REP
56.1.1)
5.
Remove the LED Bracket. (Figure 3)
(1) Remove the screw (short: x3).
(2) Remove the LED Bracket.
6.
Remove the LED Lamp PWB. (Figure 4)
(1) Remove the screw (short: x2).
(2) Remove the LED Lamp PWB.
08/2012
4-10
Figure 2 j0lj40108
Figure 3 j0lj40125
WorkCentre 5021/5019
Initial Issue