6.4.2.4 Read Temperature
Purpose
Displays the Temperature (Degrees Celsius) inside the machine on the UI.
1.
Unit: 0.1 Degree Celsius
2.
Read Range: 1098 to -488 (109.8 Degrees Celsius to -48.8 Degrees Celsius)
NOTE: For values of 1000 or higher, only the lower 3 digits are displayed. (Example:
1098 -> 098)
NOTE: A flashing number indicates that the temperature in the machine is negative.
Procedure
1.
Enter the CE Diag Mode and input 942-951 in the Chain-Link.
2.
Pressing the [Start] button displays the Temperature (Degrees Celsius) inside the
machine.
Figure 1 j0lj64011
3.
Pressing the [Stop] button causes the [End] to flash twice -> remain ON to indicate that
the process has completed.
4.
Pressing the [Clear All] button returns you to the [Chain-Link Number Entry] screen.
Initial Issue
WorkCentre 5021/5019
6.4.2.5 NVM Initialize
Purpose
Returns the NVM to its default values.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. of the item to initialize.
Chain-Link
Type
999-990
NVM Initialize - Controller
999-991
NVM Initialize - Network
999-992
NVM Initialize - IIT
999-993
NVM Initialize - MCU
999-994
NVM Initialize - DADF
999-999
NVM Initialize - All Area
3.
Pressing the [Start] button transitions to the [Check Initialization] screen. At this time, the
[CLR] and the [Start] button will be flashing.
4.
Pressing the [Start] button starts the initialization of the [NVM].
An animation will be displayed to indicate that it is in progress.
08/2012
6-95
Table 1
Overview
Initializes the NVM of the Controller.
Initializes the NVM of the Network.
Initializes the NVM of the IIT.
Initializes the NVM of the MCU.
Initializes the NVM of the DADF.
Initializes the NVM of all areas.
Figure 1 j0lj64003
General Procedures
6.4.2.4, 6.4.2.5