077-101 Regi Sensor Off Jam
BSD-ON:CH8.3,
CH4.1
The Regi Sensor did not turn OFF within the specified time after the Regi Clutch On.
Cause/Action
Check the following:
•
The Regi Sensor (Input Check [071-105]) for operation failure.
•
The Main Drive Motor (Output Check [042-001]) for operation failure.
•
The Regi Clutch (Output Check [071-001]) for operation failure.
•
The Regi Roll and Pinch Roll for transportation failure due to contamination, wear, and
deterioration.
•
The Transfer Unit for a decrease in the transportation force.
•
The Drive Gear for wear and damage.
•
A paper transportation failure due to foreign substances on the paper path.
•
Usage of out of spec paper.
If no problems are found, replace the ESS/MCU PWB.
077-103 Fusing Unit Exit Sensor Off Jam (Long)
BSD-ON:CH10.3, CH4.1,
CH10.4
After the Regi Sensor Off, the Fusing Unit Exit Sensor did not turn OFF within the specified
time.
Cause/Action
Check the following:
•
The Fusing Unit Exit Sensor (Input Check [071-106]) for operation failure.
•
The Main Drive Motor (Output Check [042-001]) for operation failure.
•
The Invert Motor (Output Check [071-003] (Exit)) for operation failure.
(When Duplex is installed)
(PL
17.1)
•
The Exit Roll and Pinch Roll for transportation failure due to contamination, wear, and
deterioration.
•
The Transfer Unit for a decrease in the transportation force.
•
The Heat Roll for wound up, stuck paper.
•
The Drive Gear for wear and damage.
•
Usage of out of spec paper.
If no problems are found, replace the ESS/MCU PWB.
Initial Issue
WorkCentre 5021/5019
(PL
15.1)
(PL
3.1)
(PL
15.1)
(PL
18.1)
(PL
7.1)
(PL
3.1)
(PL
18.1)
08/2012
2-41
077-104 Fusing Unit Exit Sensor Off Jam (Short)
BSD-ON:CH10.3, CH8.3, CH4.1,
CH10.4
The time taken for the Fusing Unit Exit Sensor to turn from ON to OFF is shorter than the spec-
ified time.
Cause/Action
Check the following:
•
The Fusing Unit Exit Sensor (Input Check [071-106]) for operation failure.
•
The Regi Sensor (Input Check [071-105]) for operation failure.
•
The Main Drive Motor (Output Check [042-001]) for operation failure.
•
The Invert Motor (Output Check [071-003] (Exit)) for operation failure.
(When Duplex is installed)
(PL
17.1)
•
The Heat Roll for wound up, stuck paper.
•
Usage of out of spec paper.
If no problems are found, replace the ESS/MCU PWB.
077-106 Fusing Unit Exit Sensor On Jam
BSD-ON:CH10.3, CH8.3,
CH4.1
The Fusing Unit Exit Sensor did not turn ON within the specified time after the Regi Clutch On.
Cause/Action
Check the following:
•
The Fusing Unit Exit Sensor (Input Check [071-106]) for operation failure.
•
The Main Drive Motor (Output Check [042-001]) for operation failure.
•
The Regi Clutch (Output Check [071-001]) for operation failure.
•
The Fusing Unit Exit Chute for improper installation and deformation.
•
The Transfer Unit for a decrease in the transportation force.
•
The Drive Gear for wear and damage.
•
The Heat Roll for wound up, stuck paper.
•
A paper transportation failure due to foreign substances on the paper path.
•
Usage of out of spec paper.
If no problems are found, replace the ESS/MCU PWB.
(PL
7.1)
(PL
15.1)
(PL
3.1)
(PL
18.1)
(PL
7.1)
(PL
3.1)
(PL
15.1)
(PL
18.1)
Status Indicator RAPs
077-101, 077-104