6.3.2.2 IIT Output Component Check List
Chain-Link Component Name
062-002
IIT Exposure Lamp
062-005
CARRIAGE MOTOR (Scan
direction)
062-006
CARRIAGE MOTOR (Return
direction)
062-091
Exchange to DADF
6.3.2.3 IOT Output Component Check List
Chain-Link
Component Name
042-001
MAIN DRIVE MOTOR On
042-002
NOHAD FAN (High Speed)
042-003
NOHAD FAN (Low Speed)
071-001
REGI. CLUTCH On
071-002
DUPLEX CLUTCH On
071-003
INVERT MOTOR (CW Phase1-2)
071-004
INVERT MOTOR (CW Phase2)
071-005
INVERT MOTOR (CCW Phase1-2)
071-006
INVERT MOTOR (CCW Phase2)
072-001
TRAY 1 FEED CLUTCH On
072-002
TRAY 2 FEED/LIFT UP MOTOR (Feed)
072-003
STM TAKEAWAY ROLL CLUTCH On
072-004
STM TAKEAWAY MOTOR On
072-005
TRAY 2 FEED/LIFT UP MOTOR (Lift Up)
072-006
MSI FEED CLUTCH On
091-001
Xero Combination
091-002
BCR AC Bias On
091-003
BCR DC Bias On
091-004
DEVE DC Bias On
091-005
BCR AC DC Bias On
092-001
TONER DISPENSE MOTOR On
094-001
BTR +Bias On
General Procedures
6.3.2.2
Table 1 IIT Output Component Check List
Connecter Level
Description
L
L: Turns ON the IIT Exposure Lamp.
Turns the Lamp ON for 180 s -> Auto OFF
4 phases eachH/L
Moves it 50 mm from current position in Scan direction -> Auto OFF Will not accept Stop instruction before Auto OFF.
switch
4 phases eachH/L
Moves it 50 mm from current position in Return direction -> Auto OFF Will not accept Stop instruction before Auto OFF.
switch
L
Turns ON the document exchange command signal to the DADF.
Table 1 IOT Output Component Check List
Connector Level
L
-
-
L
L
-
-
-
-
L
-
L
L
-
L
-
-
-
-
-
L
-
Description
L: Drives the MAIN DRIVE MOTOR.
Drives the NOHAD FAN at high speed.
Drives the NOHAD FAN at low speed.
L: Turns ON the REGI CLUTCH.
L: Turns ON the DUPLEX CLUTCH.
Drives the INVERT MOTOR in CW Phase 1-2.
Drives the INVERT MOTOR in CW Phase 2.
Drives the INVERT MOTOR in CCW Phase 1-2.
Drives the INVERT MOTOR in CCW Phase 2.
L: Turns ON the TRAY 1 FEED CLUTCH.
Performs the Paper Feed operation using TRAY 2 FEED/LIFT UP MOTOR.
L: Turns ON the STM TAKEAWAY ROLL CLUTCH.
L: Drives the STM TAKEAWAY MOTOR.
Performs the Tray Lift Up operation using TRAY 2 FEED/LIFT UP MOTOR.
L: Turns ON the MSI FEED CLUTCH.
Carries out combined operation of the following components.
•
BCR AC Bias On
•
BCR DC Bias On
•
DEVE DC Bias On
•
MAIN DRIVE MOTOR On
•
BTR -Bias On
Turns ON the BCR AC Bias.
Turns ON the BCR DC Bias.
Turns ON the DEVE DC Bias.
Turns ON the AC and DC BCR Bias.
L: Drives the TONER DISPENSE MOTOR.
Turns ON the BTR positive bias.
08/2012
6-32
Remarks
Will also turn OFF when Stop is instructed before
Auto OFF.
WorkCentre 5021/5019
Initial Issue