6.3.14 NVM PROCON
Chain-Link
NVM Name
752-007
PRC_CRU_EMPTY_STATE
752-010
PRC_DRUM_CYCLE_COUNT
752-011
PRC_DRUM_LIFE_INFO
752-015
PRC_TEMP_NOW
752-053
PRC_ATC_AVE
752-054
PRC_ATC_AMP
752-055
PRC_ATC_AVE_FAIL
752-056
PRC_ATC_AMP_FAIL
752-057
PRC_ATC_WARNING
752-058
PRC_ATC_WARNING_CNT
752-059
PRC_ATC_FAIL
752-060
PRC_ATC_FAIL_CONTINUED_CNT
752-061
PRC_ATC_AVE_FAIL_CNT
752-062
PRC_ATC_AMP_FAIL_CNT
752-063
PRC_ATC_FAIL_CNT
752-080
PRC_ATC_DOUBLE_AVE_PRE
752-081
PRC_ATC_DOUBLE_AVE
752-082
PRC_DELTA_ATC_TARGET_DIFF
752-083
PRC_TEMP_SNR
752-086
PRC_TEMP_SNR_FAIL
752-087
PRC_TEMP_SNR_FAIL_CNT
752-094
PRC_MAX_TEMP
Initial Issue
WorkCentre 5021/5019
Table 1 NVM PROCON
Setting
Setting
Range
Range
(Minimum
(Maximum
Default
Value)
Value)
Value
0
3
0
0
1023
0
0
4
0
-10
80
0
0
999
0
0
999
0
0
1
0
0
1
0
0
1
0
0
65535
0
0
1
0
0
255
0
0
65535
0
0
65535
0
0
65535
0
0
999
548
0
999
548
-999
999
0
0
1023
0
0
1
0
0
65535
0
-20
60
0
08/2012
6-63
Write
Initialization
Yes/No
Yes/No
Description
Enable
Enable
Flag empty detection state
0: Normal
1: PreNear
2: NearEmpty
3: Empty
Enable
Enable
Drum Rotation Time(Cycle Count)
uint32_t
Enable
Enable
Drum Cartridge Status(NVM. 0 to 4)
0: Normal
1: Pre-near
2: Near
3: Over
4: End
Enable
Enable
temp_now (temperature)
Enable
Enable
ATC Average Value
Enable
Enable
ATC Amplitude
Enable
Enable
ATC Average Fail
0: Normal
1: Fail
Enable
Enable
ATC Amplitude Fail
0: Normal
1: Amplitude too small
Enable
Enable
ATCwarning
Enable
Enable
ATC Warning Counter
Enable
Enable
ATCFail
Enable
Enable
ATC Fail Continuous Count
Enable
Enable
ATC Average Fail Count
Enable
Enable
ATC Amplitude Fail Count
Enable
Enable
Number of ATC Fails
Enable
Enable
ATC_2 Weighted Average Value_Previous
Enable
Enable
ATC_2 Weighted Average Value
Enable
Enable
Delta ATC_Target Deference
Enable
Enable
Temperature Sensor Value
Enable
Enable
Temperature Sensor Fail
0: Normal
1: Fail
Enable
Enable
Temperature Sensor Fail Count
Enable
Enable
Maximum temperature value
(Unit: 1 degrees C)