Xerox WorkCentre 5021 Service Documentation page 311

Hide thumbs Also See for WorkCentre 5021:
Table of Contents

Advertisement

Chain-Link
NVM Name
711-213
DADF Stamp Solenoid ON Time Adjustment
711-214
DADF Stamp Position Adjustment Side 1
(T23)
711-215
DADF Stamp Position Adjustment Side 2
(T28)
711-220
Usage of DPM Control Parameter Instructed
from the Controller
711-221
DADF DPM Control Parameter
711-272
Side 1 Side Regi Adjustment Value
(ADF-IIT Combine Adjustment Value Data 3)
711-274
Side 2 Side Regi Adjustment Value
(ADF-IIT Combine Adjustment Value Data 5)
711-276
ADF-IIT Combine Adjustment Value Data 7
711-277
ADF-IIT Combine Adjustment Value Data 8
711-278
ADF-IIT Combine Adjustment Value Data 9
711-279
ADF-IIT Combine Adjustment Value Data 10
711-280
ADF-IIT Combine Adjustment Value Data 11
711-281
ADF-IIT Combine Adjustment Value Data 12
711-282
ADF-IIT Combine Adjustment Value Data 13
711-283
ADF-IIT Combine Adjustment Value Data 14
711-284
ADF-IIT Combine Adjustment Value Data 15
711-297
Communication Fail Bypass
General Procedures
6.3.5
Table 1 NVM DADF
Setting
Default
Range
Value
step
0-20
5
2 ms
0-30
15
0.5 mm
0-40
20
0.2 mm
0-1
1
-
0-255
101
-
0-240
120
-
0-240
120
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-255
0
-
0-1
0
-
08/2012
6-42
Description
Default value: 10 ms, +30 ms/-4 ms, 2 ms increments
Default Value: 0 mm, +7.5 mm/-7.5 mm, approx. 0.5 mm increments
Default Value is 10 mm from Tail Edge
Sets the adjustment time so that the distance (step distance) is the same for every
speed.
Adjustment Value (ms) = (NVM Input Value - NVM Default Value) / Transport Speed x
1000 x 0.2 (mm step).
0: Cont DPM Parameter Reject
1: Cont DPM Parameter Accept
100th Digit: Drive Type (0: High, 1: Middle, 2: Low)
10th Digit: Loop Control
1st Digit: Pre Regist Speed
Side 1 Side Regi Adjustment Value
Side 2 Side Regi Adjustment Value
Adjustment Value Data 7 sent to IIT during ADF-IIT Combine
Adjustment Value Data 8 sent to IIT during ADF-IIT Combine
Adjustment Value Data 9 sent to IIT during ADF-IIT Combine
Adjustment Value Data 10 sent to IIT during ADF-IIT Combine
Adjustment Value Data 11 sent to IIT during ADF-IIT Combine
Adjustment Value Data 12 sent to IIT during ADF-IIT Combine
Adjustment Value Data 13 sent to IIT during ADF-IIT Combine
Adjustment Value Data 14 sent to IIT during ADF-IIT Combine
Adjustment Value Data 15 sent to IIT during ADF-IIT Combine
0: Communication Fail Bypass OFF
1: Communication Fail Bypass ON
Initial Issue
WorkCentre 5021/5019

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5019

Table of Contents