Xerox WorkCentre 5021 Service Documentation page 354

Hide thumbs Also See for WorkCentre 5021:
Table of Contents

Advertisement

6.3.20 NVM Jam Counter Clear & Initialize HFSI
Chain-Link
NVM Name
998-970
Jam Counter Clear-Tray1 Regi Sensor On Jam
998-971
Jam Counter Clear-Tray2 Feed Out#2 Sensor On Jam
998-972
Jam Counter Clear-Tray2 Regi Sensor On Jam
998-973
Jam Counter Clear-MSI Regi Sensor On Jam
998-974
Jam Counter Clear-DUP Regi Sensor On Jam
998-975
Jam Counter Clear-Regi Sensor Off Jam
998-976
Jam Counter Clear-Exit Sensor On Jam
998-977
Jam Counter Clear-Exit Sensor Off Jam
998-978
Jam Counter Clear-Paper Length Mismatch
998-980
Initialize Fault History
998-981
Initialize Jam Counter
998-982
Initialize HFSI Counter
998-983
Initialize HFSI Counter-IIT
998-984
Initialize HFSI Counter-MCU
998-985
Initialize HFSI Counter-DADF
999-990
NVM Initialize-Controller
999-991
NVM Initialize-Network
999-992
NVM Initialize-IIT
999-993
NVM Initialize-MCU
999-994
NVM Initialize-DADF
999-999
NVM Initialize-All Area
999-980
Maintenance Report
999-970
DATA All Delete
Initial Issue
WorkCentre 5021/5019
Table 1 NVM Jam Counter Clear & Initialize HFSI
Description
Paper Length Mismatch at each Tray
Clears all the Jam Counters at one go.
Refer to
Clears all the HFSI Counters at one go.
Refer to
Clears all the IIT-related HFSI Counters at one go.
Clears all the MCU-related HFSI Counters at one go.
Clears all the DADF-related HFSI Counters at one go.
Refer to
Same as above
Same as above
Same as above
Same as above
Same as above
Refer to
Initializes the Job History
Refer to
08/2012
6-85
[6.4.2.10
Jam Counter Reset].
[6.4.2.8
HFSI Counter Reset].
[6.4.2.5
NVM Initialize].
[6.4.2.7
Maintenance Report].
[6.4.2.1.2
Data All Delete].
General Procedures
6.3.20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5019

Table of Contents